BPHCG - K-5533, PINK LOTION TREND

  • MSDS: BPHCG
  • Manufacturer: PUREX INDUSTRIAL
  • Product Name: K-5533, PINK LOTION TREND
  • National Stock Number: 8520-00N031186
Product Identification

Product ID:K-5533, PINK LOTION TREND
MSDS Date:11/01/1986
FSC:8520
NIIN:00N031186
MSDS Number: BPHCG

Responsible Party
PUREX INDUSTRIAL
7300 BOLSA AVE
WESTMINSTER, CA 92684-3600
US

Emergency Phone: 614-387-6200

Info Phone: 714-890-3600

Cage: PUREX

Contractor
TURCO PRODUCTS, INC.
6200 WESTMINSTER, CA 92684-3600 US

Telephone: 614-387-6200

Cage: 0BYN5

Ingredients

BENZENESULFONIC ACID, DODECYL-, SODIUM SALT; (SODIUM LINEAR

CAS: 25155-30-0

RTECS: DB6825000

Fraction By Weight: <15%

EPA Report Quantity: 1000 LBS

DOT Report Quantity: 1000 LBS

Hazards

LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:NO Skin:NO Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:EYE/SKIN:SLIGHT IRRITANT. INHAL:NO
EFFECTS OF EXPOSURE EXPECTED. INGEST:SLIGHTLY TOXIC.
Explanation of Carcinogenicity:NOT RELEVENT
Effects of Overexposure:SEE HEALTH HAZARDS.
Medical Cond Aggravated by Exposure:NO DATA FOUND.

First Aid

First Aid:EYE:FLUSH W/WATER FOR AT LEAST 15 MINUTES. SKIN:FLUSH
W/WATER. INHAL:NO EFFECTS OF EXPOSURE EXPECTED. REMOVE TO FRESH
AIR. SUPPORT BREATHING (GIVE O2/ARTF RESP), CALL MD . INGEST:GIVE
SEVERAL GL ASSES OF WATER OR MILK TO DILUTE INGESTED MATERIAL. CALL
MD.

Fire Fighting

Flash Point Method:TCC
Flash Point:NONE
Extinguishing Media:NONE REQUIRED. USE MEDIA SUITABLE FOR SURROUNDING
FIRE .
Fire Fighting Procedures:WEAR NIOSH/MSHA APPROVED SCBA & FULL
PROTECTIVE EQUIPMENT .
Unusual Fire/Explosion Hazard:NONE

Accidental Release

Spill Release Procedures:MOP UP SPILLAGE, FLUSH OR RINSE W/WATER &
ALLOW TO DRY. DIKE AREA IF SPILLAGE IS LARGE.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

Handling

Handling and Storage Precautions:NORMAL HANDLING PROCESSES; INSIDE
STORAGE AT 40-100F RECOMMENDED.
Other Precautions:NO SPECIAL MIXING PRECAUTIONS NECESSARY. A PROGRAM OF
REGULAR CLEANING, REPAIRING AND REPLACING OF WORN-OUT PARTS AND
CONTAMINATED EQUIPMENT IS HIGHLY DESIRABLE.

Exposure Controls

Respiratory Protection:NONE REQUIRED. USE NIOSH/MSHA APPROVED
RESPIRATOR APPROPRIATE FOR EXPOSURE OF CONCERN .
Ventilation:USE W/NORMAL VENTILATION MEANS.
Protective Gloves:RUBBER OR SOFT PLASTIC GLOVES.
Eye Protection:CHEMICAL WORKERS GOGGLES .
Other Protective Equipment:NONE SPECIFIED BY MANUFACTURER.
Work Hygienic Practices:USE ADEQUATE WASHING FACILITIES. WASH HANDS OR
OTHER CONTACT AREAS THOROUGHLY. CHANGE CLOTHING IF WETTED (SUPP
DATA)
Supplemental Safety and Health
PH:6.8-7.1. HYGIENE PRACT:W/PRODUCT. DO NOT REUSE CLOTHING WETTED
W/PRODUCT BEFORE CLOTHING IS LAUNDERED.

Chemical Properties

HCC:N1
Boiling Pt:B.P. Text:212F,100C
Spec Gravity:1
pH:SUPDAT
Evaporation Rate & Reference:1 (WATER = 1)
Solubility in Water:100%
Appearance and Odor:OPAQUE PINK LIQUID.
Percent Volatiles by Volume:75

Stability

Stability Indicator/Materials to Avoid:YES
NONE SPECIFIED BY MANUFACTURER.
Stability Condition to Avoid:NONE
Hazardous Decomposition Products:NONE

Disposal

Waste Disposal Methods:FLUSH W/WATER INTO WASTE TREATMENT SYSTEMS
AND/OR I/A/W FEDERAL, STATE AND LOCAL ORDINANCES.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.